Accurate
weighing, sequencing and feeding of liquid chemicals
is absolutely mandatory during a dyeing process, no
matter what you are colouring, be it yarn, fiber, or
fabric.
SLD will take care of those series of very important
tasks, taking over the whole chemical weighing and distribution
process. It is "the right solution" for all
your chemicals. Installation, operation of SLD is easy,
thanks to its single-line weighing and distribution
technology.
SLD Liquid Chemical Distribution System will help you
to reduce excessive chemical usage caused by some operator
errors, various leakages or some extra safety margins.
Shorter operation periods, accomplished by the nature
of just-in-time chemical preparation and distribution,
also mean higher productivity. Reports show that up
to 20% cost reduction is attained in majority of dye-houses.

Product Specifications
| |
Report
generator
| |
|
Mistakes
not permitted, even when unattended |
| |
Record
of events and alarms |
|
|
Saving
time and supplies |
| |
Increasing
production capacity |
|
|
Positioning
flexibility |
| |
Easy
maintenance |
|
|
Storage
tanks level monitoring |
| |
Valve
leakage test options |
|
|
Recipe
integration |
| |
Touch screen or desktop PC options and user friendly
software |
|
|
Remote
access / remote servicing for software upgrades
|
| |
Low/high
viscosity pump options |
|
|
Mass
or volumetric measurement options |
Technical Specifications
|
SLD
Basic |
SLD
Capacity |
| Min
Input |
4
|
4
|
| Max
Input |
48
|
48
|
| Collector
|
Multi
(max 4) |
Multi
(max 4) |
| Transfer
Capacity |
1
m3/hr - 900 cycles/day |
2
m3/hr - 1800 cycles/day |
| Transfer
Speed (max) |
25-40
lt/min |
25-40
lt/min |
| Output
Type |
3
W valve (single line) or
RD 96 DU (multi line) |
3
W valve (single line) or
RD 96 DU (multi line) |
| Max
Output |
up
to 4 branches up to 20 machines |
up
to 4 branches up to 40 machines |
| Distrubition
Type |
Single
Tree or 1 x RD 96 DU |
Double
Tree or 2 x RD 96 DU |
| Flowmeter
Type |
Magnetic
(std), Mass (optional) |
Magnetic
(std), Mass (optional) |
| Measuring
Accuracy |
0.5
% or 3 gr (cc) minimum |
0.5
% or 3 gr (cc) minimum |
| Min/Max
Amounts |
40
gr (cc) / 180 kg (lt) |
40
gr (cc) / 180 kg (lt) |
| Pump
Type |
FIP
(std), Centrifugal (optional),
Gear (optional) |
FIP
(std), Centrifugal (optional),
Gear (optional) |
| Control
PC |
RD
CU (touchscreen) |
RD
CU (touchscreen) |
PDF Brochure
Click to reach the brochure